Google
Search WWW protectowire.com

Home About Us Products Applications FAQ

 

Flame Detectors and Accessories


SharpEye™ Ultraviolet Flame Detectors

The SharpEye™ 40/40-U and 40/40-UB detectors state-of-the-art design, combines industry performance requirements and up-to-date electronic microprocessor technology. The UV sensor band pass has been carefully selected to ensure the greatest degree of spectral matching to the radiant energy emissions of fire. In addition to the basic alarm evaluation circuit, the 40/40-UB incorporates the added feature of Built-in-Test (BIT)* which enables the detector to continuously perform (at predetermined time intervals) automatic full-featured test of the detector’s internal electronics.  New 5-year warranty.

40/40U - SharpEye™ Ultraviolet Detector w/Manual Test & Heated Optics
40/40UB -
SharpEye™ Ultraviolet Detector w/Built in Test & Heated Optics
• Explosion-proof • Typical 3 second response • 0-20mA stepped output & RS-485 modbus compatible
• Multiple detection levels
• 100°/95° cone of vision
• Adjustable time delay
• FM and EN54-10 (LPCB) Approved

40/40-001 - Swivel Mount for SharpEye™ 40/40 Models. Used to facilitate adjustment of the Detector’s field of view.

777161 - Air Shield for 40/40 Models. The air shield has been designed to protect the detector's viewing window from debris and dust.

 

Manuals and Reference Guides

Description File Name Format Size

40/40U-UB UV Flame Detector Product Data Sheet

DS-9227.pdf
PDF File
100k

SharpEye 40/40 Configuration Spreadsheet. Used in conjunction with DS-9227 to configure/program 40/40U Series Detectors. Produces detector complete model # based on option selection. Requires MS Excel 2000 or higher.

FDC-4040-1.6
Excel Spreadsheet
77k

SharpEye™ UV/IR Flame Detectors

The new generation of SharpEye™ UV/IR optical flame detectors, combines State-of-the-Art technology with existing proven performance equipment. Detection performance is controlled by a micro-processor and easily adapted to all environments, applications and requirements. The result is a unique and superior flame detector which provides excellent detection sensitivity with extreme immunity to false alarms.  New 5-year warranty.

40/40L - SharpEye™ UV/IR Dual Spectrum Detector w/Manual Test & Heated Optics
40/40LB - SharpEye™ UV/IR Dual Spectrum Detector w/Built in Test & Heated Optics
40/40L4 (L4B) are identical to the L (&LB) models respectively, except the IR sensor works at a wavelength of 4.5 microns and is only suitable for hydrocarbon-based fires.
 • UV/IR dual spectrum design • 150 millisecond response to saturated signal
 • 0-20mA (stepped) output • RS-485 modbus compatible • Multiple detection levels • 100°/95° cone of vision
 • User-programmable configuration • Mil-spec electronic components
 • FM & EN54-10 (LPCB) Approved

 

40/40-001 - Swivel Mount for SharpEye™ 40/40 Models. Used to facilitate adjustment of the Detector’s field of view.

 

777161 - Air Shield for 40/40 Models. The air shield has been designed to protect the detector's viewing window from debris and dust.

 

Manuals and Reference Guides

Description File Name Format Size

40/40 UV/IR Flame Detector Series Product Data Sheet

DS-9228.pdf
PDF File
99k

SharpEye 40/40 Configuration Spreadsheet. Used in conjunction with DS-9228 to configure/program 40/40L Series Detectors. Produces detector complete model # based on option selection. Requires MS Excel 2000 or higher.

FDC-4040-1.6
Excel Spreadsheet
77k

SharpEye™ IR3 Flame Detector

The SharpEye™ 40/40I is a self-contained triple spectrum flame detector. The sensor band pass has been carefully selected to ensure the greatest degree of spectral matching to the radiant energy emissions of fire, and the lowest degree of matching to non-fire stimuli. The SharpEye 40/40I is extremely sensitive. It can detect a 1x1 sq. ft. gasoline pan fire at 215 ft. in less than 5 seconds. The sensitivity is user-programmable, offering 4 ranges of detection. The patented triple IR design offers two to three times the detection distance of any conventional IR or UV/IR detector.  New 5-year warranty.

40/40I - SharpEye™ IR3 Triple Infrared Detector w/Built in Test & Heated Optics
• Triple IR spectrum design • Sensitivity selection 
• User programmable configuration
• Automatic and manual built-in test
• Explosion-proof
• 0-20mA (stepped) output • RS-485 modbus compatible
• FM, EN54-10 (LPCB) & DNV Marine Approved

 

40/40-001 - Swivel Mount for SharpEye™ 40/40 Models. Used to facilitate adjustment of the Detector’s field of view.

 

777161 - Air Shield for 40/40 Models. The air shield has been designed to protect the detector's viewing window from debris and dust.

 

Manuals and Reference Guides

Description File Name Format Size

40/40I Triple IR (IR3) Flame Detector Product Data Sheet

DS-9229.pdf
PDF File
101k

SharpEye 40/40 Configuration Spreadsheet. Used in conjunction with DS-9229 to configure/program 40/40I (IR3) Series Detectors. Produces detector complete model # based on option selection. Requires MS Excel 2000 or higher.

FDC-4040-1.6
Excel Spreadsheet
77k

SharpEye™ IR Flame Detector

The SharpEye™ 40/40R Single-IR Optical Flame Detector incorporates the advanced flame analysis algorithms employed in the SharpEye line of UV/IR and IR3 Optical Flame Detectors, combined with a cost-effective electro-mechanical design to produce a low cost flame detector. The 40/40R Flame Detector was designed to provide early warning of flaming fires involving organic (hydrocarbon fuels and gas) materials.

40/40R - SharpEye Single-IR Optical Flame Detector w/Built in Test & Heated Optics
Infrared sensor and optical filter provides maximum sensitivity
 to the CO2 emission spectral band at 4.5 micron
• 0-20 mA output and RS-485 modbus compatible
• Automatic and manual built-in test
• 90° / 90° cone of vision

• 5-year warranty

 

40/40-001 - Swivel Mount for SharpEye™ 40/40 Models. Used to facilitate adjustment of the Detector’s field of view.

 

777161 - Air Shield for 40/40 Models. The air shield has been designed to protect the detector's viewing window from debris and dust.

 

Manuals and Reference Guides

Description File Name Format Size

 40/40R Single IR Flame Detector Product Data Sheet

DS-9230.pdf
PDF File
96k

SharpEye 40/40 Configuration Spreadsheet. Used in conjunction with DS-9230 to configure/program 40/40R Series Detectors. Produces detector complete model # based on option selection. Requires MS Excel 2000 or higher.

FDC-4040-1.6
Excel Spreadsheet
77k

SharpEye™ Multi-IR Flame Detector

The SharpEye™ 40/40M is specifically designed for detection of hydrocarbon and hydrogen flames.  It detects hydrocarbon based fuel and gas fires at long distances with a high immunity to false alarms.  Its features include a heated window to eliminate condensation and icing; HART capabilities for digital communications; low power requirements, and a compact housing.

40/40M - SharpEye Multi-IR Optical Detector w/Built in Test & Heated Optics
• FM & EN54-10 (LPCB) Approved 

40/40M - SharpEye Multi-IR Flame Detector

 

40/40-001 - Swivel Mount for SharpEye™ 40/40 Models. Used to facilitate adjustment of the Detector’s field of view.

 

777161 - Air Shield for 40/40 Models. The air shield has been designed to protect the detector's viewing window from debris and dust.

 

Manuals and Reference Guides

Description File Name Format Size

 40/40M Multi-IR Flame Detector Product Data Sheet

N/A    

SharpEye 40/40 Configuration Spreadsheet. Used to configure/program 40/40 Series Detectors. Produces detector complete model # based on option selection. Requires MS Excel 2000 or higher.

FDC-4040-1.6
Excel Spreadsheet
77k


 


Home About Us Products Applications FAQ

 

 

 

 

Copyright © 2000 The Protectowire Company, Inc.
Manufacturer of Linear Heat Detection Systems